SiC & GaN power semiconductors · Engineering support from India

Custom racks and enclosures for power electronics

Racks, slide-in subracks, power-shelf chassis and cabinets for solid-state transformers (SSTs), 800 V DC data-center power and converter labs. Built to your drawing, from one prototype to a production batch.

  • From 1 unit
  • 19-inch and Open Rack
  • 800 V DC busbar layouts
  • Air or liquid cooling
  • Built to your drawing

What we build

Mechanical structures for power converters: frames, rails, panels, busbar and cooling mounts. You keep control of the electrical design.

Floor-standing 19-inch rack with perforated door

19-inch and Open Rack

19-inch racks to EIA-310 / IEC 60297 dimensions and 21-inch Open Rack (ORv3) frames, open or enclosed, with the depth, load rating and cable entry you need.

3U slide-in power-shelf chassis on telescopic slides

Slide-in subracks and power shelves

Converter modules that slide in on rails, with front handles, rear blind-mate busbar or connector positions and shelf chassis for rectifier and DC-DC modules.

Power-electronics cabinet with copper busbars on the mounting plate

Power-electronics cabinets

Low-voltage cabinets for converter stages, battery PCS and drives: mounting plates, copper busbar supports, filter and fan positions, and gland plates.

Open lab rack with covered DC busbar, earthing bar and high-voltage warning

Lab and test racks for 800 V DC

Racks for SST and 800 V / ±400 V DC prototypes: covered busbar runs, earthing points, clear access for probes, and panels that come off for rework.

Cold plate with two power modules piped to a manifold rail

Liquid-cooling mounts

Cold-plate brackets, manifold rails and drip trays positioned for your modules and hoses.

Outdoor steel enclosure with ventilation louvre

Containers and outdoor enclosures

Larger outdoor enclosures and container conversions are available on request. Tell us the size and duty and we confirm what we can offer.

Images show design renderings. Every unit is built to your drawing and specification.

Container stations for SSTs

20 ft and 40 ft container conversions for solid-state transformers and battery stations: racks, busbars, cooling and cable entry laid out to your design. Available on request. Formal type tests, for example IEC 62271-202 for medium-voltage stations, are arranged with an accredited lab when your project needs them.

40 ft container stationRacks, busbars and cooling, laid out to your design
20 ft container converted into an SST station, side door open, racks of power cells inside
20 ft containerPower-cell racks, busbars and air conditioning
40 ft container SST station in cutaway: switchgear, power-cell racks and cooling
40 ft containerSwitchgear, power-cell racks, DC output and liquid cooling

Materials and finishes

  • Sheet metal: cold-rolled steel, galvanized steel, stainless steel or aluminium, in the thickness your loads need.
  • Finish: powder coat in the RAL colour you choose, or zinc plating.
  • Busbars: copper, bare or tin-plated, with insulated supports.
  • Hardware: rails, captive fasteners, hinges, locks, handles and cable management.

Why use us

  • Small quantities welcome: one prototype rack is a normal order.
  • Engineers who know power electronics: we check creepage, earthing, airflow and service access on your drawing before anything is cut.
  • One partner for racks and semiconductors: pair the enclosure with IRONHAWK SiC MOSFETs and modules.
  • Your drawings stay yours: we sign your NDA before you share them if you ask.

How it works

We design custom racks from your drawing, your sketch or just your requirements, with your approval at each step.

A rack shown half as a red engineering wireframe and half as the finished black product
Custom designFrom your drawing to a built rack
  1. 1

    Send your requirements

    A drawing, a sketch or just the size, load, voltage and cooling. The form below lists what helps.

  2. 2

    Design review and quote

    We review the design, suggest changes, and send a price and lead time.

  3. 3

    First unit

    We build one unit for you to check and approve before the batch.

  4. 4

    Batch and delivery

    The batch is built to the approved unit and shipped with its inspection record.

Questions

  • Are your enclosures certified? We build to your drawing and the standards you name. Formal type tests, for example an IP rating to IEC 60529 or an assembly test to IEC 61439, are done at an accredited test lab and quoted separately if you need them.
  • Who is responsible for electrical safety? The electrical design and certification of the complete system stay with your system. We supply the mechanical structure to your drawing.
  • What is the lead time? It depends on the design and quantity. We confirm it in the quote.
  • What file formats do you accept? PDF, DXF, STEP and DWG. A hand sketch with dimensions is fine to start.

Request a quote

Fill in what you know. Your email app opens with the request ready to send: attach your drawing to that email, or send it to sales@ironhawksemi.com.

Your rack or enclosure

We use these details only to answer your request. We don't share them.

Talk to an engineerDevice selection, losses, thermals Startup programSmall quantities and startup pricing Get a quoteSend your part and annual volume Follow IRONHAWK on LinkedInNew parts and application notes