TO-247-4 SiC MOSFETs
SiC MOSFETs in the TO-247-4 package
650–1200 V · from 11.5 mΩ · up to 165 A · 9 parts

Overview
TO-247-4 is a through-hole power package with a fourth lead: a Kelvin source that carries the gate-drive return separately from the power source lead.
Separating the two paths keeps the voltage induced across the source lead inductance out of the gate loop, so the same die switches faster and with lower switching loss than in a three-lead TO-247.
IRONHAWK lists single SiC MOSFETs in this package at 650 V (25 and 40 mΩ), 750 V (11.5 mΩ) and 1200 V (21 to 160 mΩ).
When to use
- PFC, LLC and phase-shifted DC/DC stages and inverters built from discretes on a heatsink.
- Solar inverters, energy storage, UPS and vehicle chargers, including designs that parallel several devices per switch.
- Upgrades of TO-247-3 designs where the PCB can be changed to route the Kelvin source.
Parts
| Part number | Configuration | VDSS (V) | RDS(on) (mΩ) | ID (A) | Datasheet | Quote |
|---|---|---|---|---|---|---|
| IHSD12R021T4 | Single switch | 1200 | 21 | 100 | Datasheet | Get quote |
| IHSD12R030T4 | Single switch | 1200 | 30 | 80 | Datasheet | Get quote |
| IHSD12R040T4 | Single switch | 1200 | 40 | 60 | Datasheet | Get quote |
| IHSD12R065T4 | Single switch | 1200 | 65 | 45 | Datasheet | Get quote |
| IHSD12R080T4 | Single switch | 1200 | 80 | 35 | Datasheet | Get quote |
| IHSD12R160T4 | Single switch | 1200 | 160 | 20 | Datasheet | Get quote |
| IHSD07R012T4 | Single switch | 750 | 11.5 | 165 | Datasheet | Get quote |
| IHSD06R025T4 | Single switch | 650 | 25 | 90 | Datasheet | Get quote |
| IHSD06R040T4 | Single switch | 650 | 40 | 55 | Datasheet | Get quote |
Details
Configurations
- Single switch (9)
Common features
- Kelvin-source pin for clean, fast switching
- Through-hole TO-247-4 package
Design notes
- Connect the gate driver return only to the Kelvin source lead and the power circuit only to the power source lead. Joining them on the PCB brings back the common source inductance the fourth lead removes.
- Faster switching means higher dv/dt. Add a Miller clamp or a small gate–source capacitor if the complementary device turns on parasitically, and confirm with a double-pulse test.
- Keep the power loop of DC-link capacitor, high-side and low-side device as small as the lead spacing allows.
- Fix the device to the heatsink with screw and washer or a clip on the package body, with an insulator if the tab must be isolated. Controlled torque matters more than high torque.
- Check lead-to-lead creepage on the package drawing against your insulation standard, especially for 1200 V parts.
FAQ
Can a TO-247-4 go into a TO-247-3 footprint?
No. The pin count and order differ, so the PCB needs a new footprint with the Kelvin source routed to the gate driver.
How do I choose RDS(on) within a voltage class?
Start from RMS current: conduction loss is IRMS² × RDS(on) at the operating junction temperature. Lower-resistance parts have larger dies with more gate charge and capacitance, so at high switching frequency a higher-resistance part may give lower total loss. Compare with the datasheet switching-energy curves.
650 V or 750 V?
The 750 V part gives more margin against turn-off overshoot on the same DC link, with 11.5 mΩ for higher current. The 650 V parts suit designs where that margin is already met and less current is needed.
Why is the turn-on current peak higher than with a three-lead part?
Faster switching charges and discharges the output capacitance of the complementary device more quickly, so the turn-on current peak can rise even though switching energy falls. Check the peak against the pulsed current rating.